Harvard Apparatus offers a complete Glucose Clamp Infusion System for rats or mice including syringe pumps, swivels, tethers and catheters. Multiple syringe pumps push glucose, insulin and a drug, tracer glucose or other fluids into a 3 or 4-way connector which combines and reaches the animal via one channel of a dual channel swivel. Blood samples are taken manually or with an automated sampler on the second channel. The two-channel VAH simplifies the animal connection and PinPorts can be used to simplify injections or intermittent sampling.
Renowned syringe pump technology enhanced for academic euglycemic or hyperglycemic glucose clamp studies
The Pump 11 Elite Glucose Clamp Infusion System is a time saving syringe pump enhancement that offers quick and simple set-up using our innovative touch screen display. The built-in software capabilities reduce the potential for error in your research by providing the most accurate fluid delivery available.
The Pump 11 Elite Glucose Clamp Infusion System, is a version of our renowned syringe pump technology enhanced for academic euglycemic or hyperglycemic glucose clamp studies.
The glucose clamp capabilities provide a time saving syringe pump enhancement that offers quick and simple set-up using our innovative touch screen display.
The built-in software capabilities reduce the potential for error in your research by providing the most accurate fluid delivery available.
The Pump 11 Elite Glucose Clamp Infusion System will simplify glucose clamp experiments with the following features.
1) Animal Weight, Concentration, and Dose Rate Programming
Glucose clamp method allows the user to enter in a desired concentration, animal weight, and dose rate in the syringe pump and then uses that information to set the infusion rate automatically.
2) Change Dose Rate While Running in the Glucose Clamp method
The user has the ability to change the dose rate during infusion. This allows the execution of complex infusion procedures without the need to start and stop the process.
3) Previous Dose Rate Display
The previous dose rate setting is displayed while the pump is running, which allows for easy monitoring. When the unit is stopped, the last dose rate set and its duration is clearly displayed.
Item# | Description | Pricing |
---|---|---|
70-4504GC | Pump 11 Elite Infusion/Withdrawal Programmable Single Syringe Pump with Glucose Clamp Method | Get a Quote |
70-4505GC | Pump 11 Elite Infusion/Withdrawal Programmable Dual Syringe Pump with Glucose Clamp Method | Get a Quote |
70-4506GC | Pump 11 Pico Plus Elite Infusion/Withdrawal Programmable Dual Syringe Pump with Glucose Clamp Method | Get a Quote |
70-4507GC | Pump 11 Elite Nanomite Infusion/Withdrawal Programmable Single Syringe Pump with Glucose Clamp Method | Get a Quote |
70-4511GC | Pump 11 Pico Plus Elite Infusion/Withdrawal Programmable Single Syringe Pump with Glucose Clamp Method | Get a Quote |
The Pump 11 Elite Glucose Clamp Infusion System, is a version of our renowned syringe pump technology enhanced for academic euglycemic or hyperglycemic glucose clamp studies.
The glucose clamp capabilities provide a time saving syringe pump enhancement that offers quick and simple set-up using our innovative touch screen display. The built-in software capabilities reduce the potential for error in your research by providing the most accurate fluid delivery available.
Features:
The Pump 11 Elite Glucose Clamp Infusion System will simplify glucose clamp experiments with the following capabilities:
1) Animal Weight, Concentration, and Dose Rate Programming
Glucose clamp method allows the user to enter in a desired concentration, animal weight, and dose rate in the syringe pump and then uses that information to set the infusion rate automatically.
2) Change Dose Rate While Running in the Glucose Clamp method
The user has the ability to change the dose rate during infusion. This allows the execution of complex infusion procedures without the need to start and stop the process.
3) Previous Dose Rate Display
The previous dose rate setting is displayed while the pump is running, which allows for easy monitoring. When the unit is stopped, the last dose rate set and its duration is clearly displayed.
Specifications | 70-4504GC | 70-4505GC | 70-4506GC | 70-4507GC | 70-4511GC |
---|---|---|---|---|---|
Accuracy | ±0.5% | ±0.5% | ±0.35% | ±0.5% | ±0.35% |
Syringes | 1 | 2 | 2 | 1 | 1 |
Flow Rate Minimum | 1.26 pl/min | 1.26 pl/min | 0.54 pl/min | 3.66 pl/min | 0.54 pl/min |
Flow Rate Maximum | 88.4 ml/min | 26.02 ml/min | 11.7 ml/min | 3.818 ml/min | 39.77 ml/min |
Classification | Class I | Class I | Class I | Class I | Class I |
Dimensions Control Box LxDxH in cm | 9.0 x 7.0 x 6.0 (22.6 x 17.78 x 15.0) | 9.0 x 7.0 x 6.0 (22.6 x 17.78 x 15.0) | 9.0 x 7.0 x 6.0 (22.6 x 17.78 x 15.0) | 9.0 x 7.0 x 3.67 (22.6 x 17.78 x 9.32) | 9.0 x 7.0 x 6.0 (22.6 x 17.78 x 15.0) |
Dimensions Remote Box LxDxH in cm | N/A | N/A | N/A | 2.5 x 2.0 x 7.5 (6.35 x 5.08 x 19.05) | N/A |
Display | 4.3″ WQVGA TFT Color Display with Touchpad | 4.3″ WQVGA TFT Color Display with Touchpad | 4.3″ WQVGA TFT Color Display with Touchpad | 4.3″ WQVGA TFT Color Display with Touchpad | 4.3″ WQVGA TFT Color Display with Touchpad |
Drive Motor | 0.9° Stepper Motor | 0.9° Stepper Motor | 0.9° Stepper Motor | 1.8° Stepper Motor | 0.9° Stepper Motor |
Environmental Humidity | 20% to 80% RH, non condensing | 20% to 80% RH, non condensing | 20% to 80% RH, non condensing | 20% to 80% RH, non condensing | 20% to 80% RH, non condensing |
Environmental Operating Temperature English | 40°F to 104°F | 40°F to 104°F | 40°F to 104°F | 40°F to 104°F | 40°F to 104°F |
Environmental Operating Temperature Metric | 4°C to 40°C | 4°C to 40°C | 4°C to 40°C | 4°C to 40°C | 4°C to 40°C |
Environmental Storage Temperatue English | 14°F to 158°F | 14°F to 158°F | 14°F to 158°F | 14°F to 158°F | 14°F to 158°F |
Environmental Storage Temperatue Metric | -10°C to 70°C | -10°C to 70°C | -10°C to 70°C | -10°C to 70°C | -10°C to 70°C |
I O TTL Connectors | 15 pin D-Sub Connector | 15 pin D-Sub Connector | 15 pin D-Sub Connector | 15 pin D-Sub Connector | 15 pin D-Sub Connector |
Input Power | 12-30 VDC | 12-30 VDC | 12-30 VDC | 12-30 VDC | 12-30 VDC |
Installation Category | II | II | II | II | II |
Max Linear Force | 35 lbs at 100% Force | 35 lbs at 100% Force | 35 lbs at 100% Force | 11 lbs at 100% Force | 35 lbs at 100% Force |
Mode of Operation | Glucose Clamp | Glucose Clamp | Glucose Clamp | Glucose Clamp | Glucose Clamp |
Motor Drive Control | Microprocessor with 1/16 microstepping | Microprocessor with 1/16 microstepping | Microprocessor with 1/16 microstepping | Microprocessor with 1/16 microstepping | Microprocessor with 1/16 microstepping |
Net Weight English | 4.6 lb | 4.6 lb | 4.6 lb | Control Box (4.32 lb)
Remote Mechanism (1.01 lb) |
4.6 lb |
Net Weight Metric | 2.1 kg | 2.1 kg | 2.1 kg | Control Box (1.96 kg)
Remote Mechanism (0.458 kg) |
2.1 kg |
No of Syringes | 1 | 2 | 2 | 1 | 2 |
Non Volatile Memory | Storage of all settings | Storage of all settings | Storage of all settings | Storage of all settings | Storage of all settings |
Number of Microsteps per one rev of Lead Screw | 15,360 | 15,360 | 20,480 | 3,200 | 20,480 |
Pollution Degree | 1 | 1 | 1 | 1 | 1 |
Pump Configuration | Single | Dual | Dual | Single | Dual |
Pump Function | Infuse/Withdraw, Programmable with Glucose Clamp Method | Infuse/Withdraw, Programmable with Glucose Clamp Method | Infuse/Withdraw, Programmable with Glucose Clamp Method | Infuse/Withdraw, Programmable with Glucose Clamp Method | Infuse/Withdraw, Programmable with Glucose Clamp Method |
Pusher Travel Rate Maximum | 159.8 mm/min | 159.8 mm/min | 71.55 mm/min | 159.8 mm/min | 71.55 mm/min |
Pusher Travel Rate Minimum | 0.18 µm/min | 0.18 µm/min | 0.068 µm/min | 0.18 µm/min | 0.68 µm/min |
Regulatory Certifications | CE, ETL (UL, CSA), WEEE, EU RoHS, CB Scheme | CE, ETL (UL, CSA), WEEE, EU RoHS, CB Scheme | CE, ETL (UL, CSA), WEEE, EU RoHS, CB Scheme | CE, ETL (UL, CSA), WEEE, EU RoHS, CB Scheme | CE, ETL (UL, CSA), WEEE, EU RoHS, CB Scheme |
Step Rate Maximum | 26 µsec/ | 26 µsec/ | 26 µsec/ | 52 µsec/ | 26 µsec/ |
Step Rate Minimum | 27.5 sec/µstep | 27.5 sec/µstep | 27.5 sec/µstep | 27.5 sec/µstep | 27.5 sec/µstep |
Syringe Size Maximum | 60 ml | 10 ml | 10 ml | 1 ml | 10 ml |
Syringe Size Minimum | 0.5 µl | 0.5 µl | 0.5 µl | 0.5 µl | 0.5 µl |
USB Connectors | Type B | Type B | Type B | Type B | Type B |
Voltage Range | 100-240 VAC, 50/60 Hz | 100-240 VAC, 50/60 Hz | 100-240 VAC, 50/60 Hz | 100-240 VAC, 50/60 Hz | 100-240 VAC, 50/60 H |
Shichun Du, Hui Wu, Xiao Xu, Ying Meng, Fangzhen Xia, Hualing Zhai & Yingli Lu (2014 ) Tracing Fasting Glucose Fluxes with Unstressed Catheter Approach in Streptozotocin Induced Diabetic Rats Journal of Diabetes Research
Hui Wu, Chunhua Sui, Hui Xu, Fangzhen Xia, Hualing Zhai, Huixin Zhang, Pan Weng, Bing Han, Sichun Du, and Yingli Lu (2014 ) The GLP-1 Analogue Exenatide Improves Hepatic and Muscle Insulin Sensitivity in Diabetic Rats: Tracer Studies in the Basal State and during Hyperinsulinemic-Euglycemic Clamp Journal of Diabetes Research
Qin Fu, Bing Xu, Yongming Liu, Dippal Parikh, Jing Li, Ying Li, Yuan Zhang, Christian Riehle, Yi Zhu, Tenley Rawlings, Qian Shi, Richard B. Clark, Xiongwen Chen, E. Dale Abel & Yang K. Xiang (2014 ) Insulin Inhibits Cardiac Contractility by Inducing a Gi-Biased β2-Adrenergic Signaling in Hearts Diabetes Journal
Harvard Apparatus Pump 11 Elite GC: Intuitive Touch Screen with Glucose Clamp Software – Program Animal Weight, Concentration and Dose Rate Without a PC – Ability to Change Dose Rate While Running Previous Dose Rate Display to Simplify Data Recording