The PHD ULTRA™ Nanomite is a single syringe infusion/withdrawal programmable syringe pump with a flow rate range of 3.66 pl/min to 3.818 ml/min with 11 lbs of adjustable force across the entire flow rate range. It can accommodate syringes from 0.5 µl to 1 ml. The PHD ULTRA™ Nanomite Syringe Pump is very easy to use with an LCD color touch screen and icon interface. This pump allows you to create, save and run simple to complex Methods without a PC. The Method profiles available on this pump are Constant Rate, Ramp, Stepped, Bolus, Concentration, Gradient (binary or ternary), Pulse and Autofill. Delays can be set using the real and relative time clocks. The Message Area of the touch screen is used to display helpful instructions for the currently displayed screen. It is also used to display error or warning messages to indicate problem conditions in a Method or error conditions during pump operation. The Run Screen shows all of the pump parameters on one screen for easy review.
The PHD ULTRA™ Nanomite is a single syringe infusion/withdrawal programmable syringe pump with a flow rate range of 3.66 pl/min to 3.818 ml/min with 11 lbs of adjustable force across the entire flow rate range. It can accommodate syringes from 0.5 µl to 1 ml.
Features:
Applications:
The PHD ULTRA™ Nanomite Syringe Pump is very easy to use with an LCD color touch screen and icon interface. This pump allows you to create, save and run simple to complex Methods without a PC. The Method profiles available on this pump are Constant Rate, Ramp, Stepped, Bolus, Concentration, Gradient (binary or ternary), Pulse and Autofill. Delays can be set using the real and relative time clocks.
The Message Area of the touch screen is used to display helpful instructions for the currently displayed screen. It is also used to display error or warning messages to indicate problem conditions in a Method or error conditions during pump operation. The Run Screen shows all of the pump parameters on one screen for easy review.
The software is organized into three main navigational branches, the quick start Methods, user-defined Methods, and system settings. You can control operations directly through the touch screen or remotely from an independent computer or device via the external I/O interface.
The PHD ULTRA™ Nanomite has a footswitch input, RS-232 and USB serial ports for computer control, RS-485 ports for daisy chaining pumps and Digital I/O for external control via an independent computer or device. There is also an option for daisy chaining pumps through the RS-232 (RJ-11) ports. This option must be ordered at the time the pump is ordered.
This pump consists of a control unit, an injection unit, a 6 foot cable to connect the two units and a footswitch.
Specifications | 70-3601 |
---|---|
Accuracy | ±0.5% |
Classification | Class I |
Dimensions Control Box LxDxH in cm | 12 x 8.5 x 4.38 (30.5 x 21.6 x 11.1) |
Dimensions Mechanism LxDxH in cm | 2.5 x 2.0 x 7.5 (6.35 x 5.08 x 19.05) |
Display | 4.3" WQVGA TFT Color Display with Touchpad |
Drive Motor | 1.8° Stepper Motor |
Environmental Humidity | 20% to 80% RH, non condensing |
Environmental Operating Temperature English | 40°F to 104°F |
Environmental Operating Temperature Metric | 4°C to 40°C |
Environmental Storage Temperatue English | 14°F to 158°F |
Environmental Storage Temperatue Metric | -10°C to 70°C |
Flow Rate Maximum | 367.4 pl/min using 50 µl syringe |
Flow Rate Minimum | 1.906 ml/min using 500 µl syringe |
I O TTL Connectors | 15 pin D-Sub Connector |
Input Power | 75 W, 0.5 A fuse |
Installation Category | II |
Max Linear Force | 11 lbs @ 100% Force Selection |
Mode of Operation | Continuous |
Motor Drive Control | Microprocessor with 1/16 microstepping |
Net Weight Control Box English | 4.55 lb |
Net Weight Control Box Metric | 2.06 kg |
Net Weight Remote Mechanism English | 1.01 lb |
Net Weight Remote Mechanism Metric | 0.458 kg |
No of Syringes | 1 |
Non Volatile Memory | Storage of all settings |
Number of Microsteps per one rev of Lead Screw | 3,200 |
Pollution Degree | 1 |
Pump Configuration | Remote |
Pump Function | Infuse/Withdraw, Programmable |
Pusher Travel Rate Maximum | 228.97 mm/min |
Pusher Travel Rate Minimum | 0.433 µm/min |
RS 232 Connectors | 9 pin D-Sub Connector |
Regulatory Certifications | CE, ETL (UL, CSA), WEE, EU RoHS & CB Scheme |
Step Rate Maximum | 52 µsec/µstep |
Step Rate Minimum | 27.5 sec/µstep |
Syringe Rack Type | Standard Rack |
Syringe Size Maximum | 500 µl |
Syringe Size Minimum | 50 µl |
USB Connectors | Type B |
Voltage Range | 100-240 VAC, 50/60 Hz |
Morris, Susan H. PhD, Howard, Jason J. MD; Rasmusson, Douglas D. PhD & El-Hawary, Ron MD (2015) Validity of Transcranial Motor Evoked Potentials as Early Indicators of Neural Compromise in Rat Model of Spinal Cord Compression Spine: An International Journal for the study of the spine
Laura C. Manella, Samuel Alperin & Christiane Linster (2013) Stressors impair odor recognition memory via an olfactory bulb-dependent noradrenergic mechanism Frontiers in Integrative Neuroscience
Antonio Riccio, Yan Li, Evgeny Tsvetkov,Svetlana Gapon, Gui Lan Yao, Kiersten S. Smith, Elif Engin, Uwe Rudolph, Vadim Y. Bolshakov & David E. Clapham (2014) Decreased Anxiety-Like Behavior and Gαq/11-Dependent Responses in the Amygdala of Mice Lacking TRPC4 Channels The Journal of Neuroscience
Jeong Ha Yoo, Deok Ha Woo, Mi-Sook Chang & Myung-Suk Chun (2014) Microfluidic based biosensing for Escherichia coli detection by embedding antimicrobial peptide-labeled beads Sensors & Actuators B: Chemical
Zhidan Liang, Claire M. Schmerberg & Lingjun Li (2014) Mass spectrometric measurement of neuropeptide secretion in the crab, Cancer borealis, by in vivo microdialysis Analyst