The "ml" Syringe Pump Module is designed as a low cost, highly precise, single syringe infuse/withdraw pump capable of low to moderate back pressures.
There is one version of the “ml” Pump Module available at this time. A dual “ml” Pump Module version can be produced upon customer request. Typically, the “ml” Modular Pumping Component holds one syringe of any make, from 0.5ul to 60ml. The inside diameter of the syringe and desired flow rate are entered via your PC, and the internal microprocessor drives a precision stepper motor to produce accurate fluid flow. This unit is designed to operate inside an enclosure, cabinet, or on top of a bench. The board may be removed for “remote” operation.
Two Modes of Operation - Constant Flow Rateand Volume Dispense
The “ml” Pump Module will operate continuously in RATE mode or accurately dispense a specific amount of fluid in VOLUME mode. When starting the pump, RATE mode will be the default mode. To operate in Volume mode, set a target volume and the pump will change modes to suit the desired operation. This is the safest way to use the “ml” Pump Module. The pump will automatically stop when target volume is dispensed.
Smooth Flow
New micro-stepping pump profiles deliver very smooth and consistent flow.
Location Requirements for the Syringe Pump
This pump module was designed to operate inside an enclosure, cabinet, or on top of a bench/table. The circuit board may be removed to a “remote” location if desired.
Specifications | 70-2219 | 70-2226 |
---|---|---|
of Syringes | 1 | 1 |
Accuracy | ±0.5 | ±0.5 |
Average Linear Force | 25 lb | 25 lb |
Communications | RS-232 with simple command language | RS-232 with simple command language |
Connectors | 9-pin D-sub; single RS-232 port | 9-pin D-sub; single RS-232 port |
Depth English | 4.25 in | 4.25 in |
Depth Metric | 10.8 cm | 10.8 cm |
Display | None | None |
Drive Control | L/R Drive, 0.75A per phase, 1/4 stepping | L/R Drive, 0.75A per phase, 1/4 stepping |
Drive Lead Screw Pitch | 1/4 • 20 threads per inch | 1/4 • 20 threads per inch |
Drive Ratio | 2.4:1 | 2.4:1 |
Environmental Humidity | 20 to 80% RH non-condensing | 20 to 80% RH non-condensing |
Environmental Operating Temperature Metric | 0 to +35 C (natural convection cooling)**Note: operating temperature may be extended with forced air cooling | 0 to +35 C (natural convection cooling)**Note: operating temperature may be extended with forced air cooling |
Flow Rate Maximum | 26.56 ml/min (with 50/60 ml syringe) | 26.56 ml/min (with 50/60 ml syringe) |
Flow Rate Minimum | 0.001 ul/hr (with 0.5 µl syringe) | 0.001 ul/hr (with 0.5 µl syringe) |
Height English | 5.3 in | 5.3 in |
Height Metric | 13 cm | 13 cm |
Keypad | None | None |
Limit Switch | End of limit travel mechanical stop | End of limit travel mechanical stop |
Motor | 0.9° step angle motor | 0.9° step angle motor |
Mounting Holes | Mounting holes for (4) #8 screws | Mounting holes for (4) #8 screws |
Mounting Length English | 9 in | 9 in |
Mounting Length Metric | 24 cm | 24 cm |
Mounting Width English | 3.75 in | 3.75 in |
Mounting Width Metric | 9.5 cm | 9.5 cm |
Net Weight English | 2.8 lbs | 2.8 lbs |
Net Weight Metric | 1.27 kg | 1.27 kg |
Pump Function | Infuse/Withdraw | Infuse/Withdraw |
Pusher Travel Rate Maximum | 47.6 mm/min | 47.6 mm/min |
Pusher Travel Rate Minimum | 2.9068 mm/min | 2.9068 mm/min |
Step Rate Maximum | 416.7 msec/step | 416.7 msec/step |
Step Rate Minimum | 6.8 sec/step | 6.8 sec/step |
Syringe Rack Type | Holds 1 syringe made from either glass or plastic | Holds 1 syringe made from either glass or plastic |
Syringe Size Maximum | 50-60 ml | 50-60 ml |
Syringe Size Minimum | 0.5 µl | 0.5 µl |
Type | Microprocessor single syringe, infusion/withdraw | Microprocessor single syringe, infusion/withdraw |
Voltage Range | (+)15 to +40VDC (12W min) (user supplied) | (+)15 to +40VDC (12W min) (included) |
Width English | 9.5 in | 9.5 in |
Width Metric | 24.1 cm | 24.1 cm |