The MidiVent Model 849 Ventilator is a quiet, compact and light weight ultra low volume ventilator. While it was designed specifically for large mice, the Midivent can be used for any animal (e.g. small rats, shrew, hamster) which requires tidal volumes in the range of 60 to 700 µl and respiratory rates of 60 to 400 breaths per minute.
The extremely light weight and compact construction, in addition to the convenient rod clamp, allow the MidiVent ventilator to be positioned directly next to the animal.
See Full Description for complete details.
The MidiVent Model 849 Ventilator is a quiet, compact and light weight ultra low volume ventilato designed specifically for large mice. it can be used for any animal (e.g. small rats, shrew, hamster) which requires tidal volumes in the range of 60 to 700 µl and respiratory rates of 60 to 400 breaths per minute.
The MidiVent Ventilator is a constant-volume respiration pump operating on the Starling principle. Unlike conventional units for larger animals, this ventilator employs a rotary plunger and has no valves. During each ventilation cycle, the plunger performs a synchronized forward and rotating movement. Cleverly arranged bores and channels in the cylinder and plunger control inspiration and expiration during each stroke of the plunger.
The extremely light weight and compact construction, in addition to the convenient rod clamp, allow the MidiVent ventilator to be positioned directly next to the animal. Typical setups with larger ventilators produce large tubing and instrument dead space volumes. These larger volumes introduce greater system compliance which can affect the accuracy with which the full tidal volume is introduced into the animal's lungs. With the MidiVent, the tidal volume error due to system compliance is reduced to 5 µl.
Tidal volume and respiration rate can be set exactly to the values required for mouse ventilation. The level of precision and control available to the investigator minimizes the danger of hyperventilation or hypoventilation.
The tidal volume can be varied continuously from 60 to 700 ul during operation without having to interrupt ventilation. The respiration rate is also continuously adjustable from 60 to 400 strokes/min. The expired air can be recovered at the collection port for sampling, recycling or for the generation of a positive end-expiratory pressure (PEEP). Room air or any non-explosive gas mixture can be used to feed the pump intake using the special connection tubing PY2 73-3077.
The system is supplied with a 1.5 mm OD tracheal cannula and a 1.5 mm OD intubation cannula for the mice. For other size animals, additional intuubation or tracheal cannula sizes may be needed.
A multi-gas inlet adapter is available for the MidiVent so that alternate gas mixtures and nebulized substances are delivered to thr MidiVent inlet port at atmospheric pressure. The adapter provides ports for multiple selectable gas mixture (hypoxic, anesthetic...) and a port for the Aerosol Nebulizer.
Specifications | 73-4120 | 73-4119 |
---|---|---|
AC Adapter Weight English | 0.7 lb | 0.7 lb |
AC Adapter Weight Metric | 0.3 kg | 0.3 kg |
Certifications | CE | CE |
Control Modes | Volume | Volume |
Depth English | 7.9 in | 7.9 in |
Depth Metric | 20 cm | 20 cm |
Display | none | none |
Gas Supply | Room air or non-flammable mixed gas | Room air or non-flammable mixed gas |
Height English | 3.1 in | 3.1 in |
Height Metric | 8 cm | 8 cm |
I E Ratio | 1:1 | 1:1 |
I E Ratio UOM | % | % |
Model | MidiVent | MidiVent |
Net Weight English | 2.2 lb | 2.2 lb |
Net Weight Metric | 1 kg | 1 kg |
Number of Animals | 1 | 1 |
PEEP | Provided via attachment of water column | Provided via attachment of water column |
Respiration Rate Maximum | 400 breaths/min | 400 breaths/min |
Respiration Rate Minimum | 60 breaths/min | 60 breaths/min |
Respiratory Rate Note | Continuously adjustable from 60 to 400 breaths/min | Continuously adjustable from 60 to 400 breaths/min |
Sigh Frequency | none | none |
Sigh Pressure | Not available | Not available |
Species | Large Mice, Small Rats | Large Mice, Small Rats |
Stroke Volume Note | Continuously adjustable from 0 to 130 µl | Continuously adjustable from 0 to 130 µl |
Tidal Volume Maximum | 700 ul/stroke | 700 ul/stroke |
Tidal Volume Minimum | 60 ul/stroke | 60 ul/stroke |
Voltage Range | 110 VAC | 230 VAC |
Weight Range Maximum | 100 g | 100 g |
Weight Range Minimum | 5 g | 5 g |
Width English | 3.9 in | 3.9 in |
Width Metric | 10 cm | 10 cm |
HannahT. Nickles , Migle Sumkauskaite , Xin Wang , Ingmar Wegner , Michael Puderbach , Wolfgang M. Kuebler (2014 ) Mechanical ventilation causes airway distension with proinflammatory sequelae in mice Am J Physiolo Lung Cell Mol Physiol