The new “µl” Pump Module is a low cost, highly precise, single syringe infuse/withdraw pump capable of low to moderate back pressures. It is available in one version only and will hold one syringe of any make from 0.5 µl to 1 ml. The inside diameter of the syringe and desired flow rate are entered via the RS-232 serial port, and the internal microprocessor drives a precision stepper motor to produce accurate fluid flow. This unit is designed to operate inside an enclosure, cabinet, or on top of a bench. The board may be removed for “remote” operation.
Two Modes of Operation - Constant Flow Rate and Volume Dispense
The “µl” Pump Module will operate continuously in RATE mode or accurately dispense a specific amount of fluid in VOLUME mode. When starting the pump, RATE mode will be the default mode. To operate in Volume mode, set a target volume and the pump will change modes to suit desired operation. This is the safest way to use the “µl” Pump Module. The pump will automatically stop when target volume is dispensed.
Smooth Flow
New micro-stepping pump profiles deliver very smooth and consistent flow.
Location Requirements for the Syringe Pump
Protecting Small, Fragile Syringes
The “µl” Pump Module will hold microliter size syringes down to 0.5µl size. These small syringes have fine wire plungers that may be damaged if allowed to bottom out. The “µl” Pump Module is equipped with adjustable limit switches on the bottom side of the mounting plate. Make sure to adjust the limit switches to prevent damage to small syringes.
Specifications | 70-2220 | 70-2225 |
---|---|---|
of Syringes | 1 | 1 |
Accuracy | 0.5 | 0.5 |
Accuracy UOM | % | % |
Average Linear Force | 6 | 6 |
Average Linear Force UOM | lb (maximum) | lb (maximum) |
Communications | RS-232 with simple command language | RS-232 with simple command language |
Connectors | RS-232 4 pin RJ-11 telephone jack; dual RS-232 ports DC Power 4-pin Header (Friction lock)" |
RS-232 4 pin RJ-11 telephone jack; dual RS-232 ports DC Power 4-pin Header (Friction lock) |
Depth English | 3.25 | 3.25 |
Depth English UOM | in | in |
Depth Metric | 8.3 | 8.3 |
Depth Metric UOM | cm | cm |
Display | None | None |
Drive Control | L/R Drive, 0.75A per phase, 1/4 stepping | L/R Drive, 0.75A per phase, 1/4 stepping |
Drive Lead Screw Pitch | 48 threads per inch (1/4-48) | 48 threads per inch (1/4-48) |
Drive Ratio | 1:1 (Direct Drive) | 1:1 (Direct Drive) |
Environmental Humidity | 20 to 80% RH non-condensing | 20 to 80% RH non-condensing |
Environmental Operating Temperature Metric | 0 to +35 | 0 to +35 |
Environmental Operating Temperature Metric UOM | °C (natural convection cooling)**Note: operating temperature may be extended with forced air cooling | °C (natural convection cooling)**Note: operating temperature may be extended with forced air cooling |
Environmental Storage Temperatue Metric | +20 to +70 | +20 to +70 |
Environmental Storage Temperatue Metric UOM | °C | °C |
Flow Rate Maximum | 0.854 | 0.854 |
Flow Rate Maximum UOM | ml/min (with 1 ml syringe) | ml/min (with 1 ml syringe) |
Flow Rate Minimum | 0.0014 | 0.0014 |
Flow Rate Minimum UOM | µl/hr with 0.5 µl syringe | µl/hr with 0.5 µl syringe |
Height English | 4.5 | 4.5 |
Height English UOM | in | in |
Height Metric | 11.4 | 11.4 |
Height Metric UOM | cm | cm |
Keypad | None | None |
Limit Switch | One for each direction (end of travel) | One for each direction (end of travel) |
Motor | 0.9° step angle motor | 0.9° step angle motor |
Mounting Holes | Mounting holes for (4) #8 screws | Mounting holes for (4) #8 screws |
Mounting Length English | 8.75 | 8.75 |
Mounting Length English UOM | in | in |
Mounting Length Metric | 22.2 | 22.2 |
Mounting Length Metric UOM | cm | cm |
Mounting Width English | 2.75 | 2.75 |
Mounting Width English UOM | in | in |
Mounting Width Metric | 7 | 7 |
Mounting Width Metric UOM | cm | cm |
Net Weight English | 1.85 | 1.85 |
Net Weight English UOM | lbs | lbs |
Net Weight Metric | 0.84 | 0.84 |
Net Weight Metric UOM | kg | kg |
Pump Function | Infuse/Withdraw | Infuse/Withdraw |
Pusher Travel Rate Maximum | 47.6 | 47.6 |
Pusher Travel Rate Maximum UOM | mm/min | mm/min |
Pusher Travel Rate Minimum | 2.9 | 2.9 |
Pusher Travel Rate Minimum UOM | µm/min | µm/min |
Step Rate Maximum | 416.7 | 416.7 |
Step Rate Maximum UMO | µsec/step | µsec/step |
Step Rate Minimum | 6.8 | 6.8 |
Step Rate Minimum UOM | sec/step | sec/step |
Syringe Rack Type | Holds 1 syringe made from either glass or plastic | Holds 1 syringe made from either glass or plastic |
Syringe Size Maximum | 1 | 1 |
Syringe Size Maximum UOM | ml | ml |
Syringe Size Minimum | 0.5 | 0.5 |
Syringe Size Minimum UOM | µl | µl |
Type | Microprocessor single syringe, infusion/withdraw | Microprocessor single syringe, infusion/withdraw |
Voltage Range | (+)12VDC, 5%, 1A (12W) (User supplied) | (+)12VDC, 5%, 1A (12W) (User supplied) |
Width English | 9.25 | 9.25 |
Width English UOM | in | in |
Width Metric | 23.5 | 23.5 |